Now the Gemalto diagnostic should show that version 8.
SAFENET SENTINEL DRIVER UNINSTALL INSTALL
When the command terminates, go to FAQ 3519 and download and install the version 8.11 of the run-time installer. Drag the haspdinst.exe from the Explorer window to the console window and add the required parameters. Open a command-line console (cmd) as adminħ. Open "Windows Explorer" and go to the directory where you install WINDEV 27.Ħ. If a service named "HASP Loader" is running then stop it.ģ. The solution is to replace this version 8.21 with the version 8.11.
SAFENET SENTINEL DRIVER UNINSTALL UPGRADE
This version 8.21 is not compatible with the WDMAJCLE.EXE program( the app that can upgrade your dongle). Mention that you have followed the advice in technical notes 6284.Īll product names are trademarks or registered trademarks of their respective owners.HASPDINST is needed for removing the "Run-time package" version 8.21.
If the USB dongle still is not detected, contact IAR Systems Customer Care for assistance. The suggestions above usually establish the connection (for LMS1) to the USB dongle. If the USB dongle is shown as an unknown device in the Windows Device Manager, then try Technical Note 67644. This is the last of the regular remedial actions for LMS1, but there is one final action to try: Check the USB port in the Windows Device Manager.
SAFENET SENTINEL DRIVER UNINSTALL DRIVERS
Use the Add/Remove Programs function from the Control Panel to uninstall the Sentinel Protection Installer and Sentinel System Driver Installer (if present). This action removes the driver subsystem that communicates with parallel port dongles. Can I delete SafeNet Sentinel You can remove the installer programs and drivers as follows: Unplug all HASP keys. Action D: Remove the dongle driver support for parallel port dongles If Windows does not detect the dongle, continue with next action. Start the application SetupSysDriver.exe located in C:\Program Files (x86)\Common Files\SafeNet Sentinel\Sentinel System Driver\.Stop the parallel port driver subsystem in the dongle driver. Action C: Change the settings for the dongle driver Reinstall the driver, version 7.5.2, as described in Technical Note 200922.Important – If there are several items in Add/Remove Programs called Sentinel System Driver, perform Uninstall on ALL of them.Choose Start > Settings > Control Panel > Add/Remove Programs.Close all IAR Systems applications, for example IAR Embedded Workbench and IAR License Manager.Make sure that only the relevant dongle driver (for LMS1) is installed. Action B: Remove and reinstall the dongle driver Install dongle driver 7.5.2 as described in Technical Note 200922.Install IAR License Manager 1.29.1 as described in Technical Note 14255.Important - disconnect the USB dongle from the PC.
SAFENET SENTINEL DRIVER UNINSTALL SOFTWARE
Make sure to use latest software for LMS1: It also contains an option that allows you to call the original installer to modify, repair, or remove the installation.
Action A: Install IAR License Manager 1.29.1 and dongle driver 7.5.2 Sentinel System Driver contains a configuration program called SetupSysDriver.exe to allow you configure the driver, if necessary. The following actions can be tried individually, but often it is best to perform them top down.
When a USB dongle isn’t detected by the computer, a typical message in LMS1 is: ‘No valid license found for this product’. Here follow several suggestions for troubleshooting a USB dongle. Note: - This applies to legacy versions of IAR Embedded Workbench (2013 and older) which used License Management System version 1 (LMS1).